CALCulate[1|2|3|4]:LIMit:LOWer:SEGMent:CLEar command
Deletes a segment from the lower limit line.$Ilimit lines;deleting lower segment
Command Syntax: CALCulate[1|2|3|4]:LIMit:LOWer:SEGMent:CLEar <number>|
<bound>
<number> ::= a real number (NRf data)
limits: -9.9e37:9.9e37
(depend upon displayed X-axis value)
<bound> ::= MAX|MIN
Example Statements: OUTPUT 711;":Calc3:Limit:Low:Segment:Cle 1.99693e+37"
OUTPUT 711;"CALC:LIMIT:LOW:SEGMENT:CLE 2.15257e+37"
Attribute Summary: Option: not applicable
Synchronization Required: no
Preset State: not applicable
SCPI Compliance: instrument-specific
Description:
This command deletes any segment which contains the X-axis value you specify. Adjacent segments are
not affected, although the limit line may be discontinuous.
The value entered for a limit line segment is unitless.
To delete all segments of a lower limit line, send CALC:LIM:LOW:CLE.
CALCulate