148 FieldFox User’s Guide
Data Analysis Features
The following features can be used after a measurement to analyze the results.
In this Chapter
All about Markers ................................................ 148
About Delta Markers ........................................... 149
Marker Table ......................................................... 151
Coupled Markers .................................................. 151
Marker Colors ....................................................... 152
Marker Trace (CAT and NA Mode) ................... 152
Marker Trace (SA Mode) .................................... 152
Marker Format ..................................................... 153
Searching with Markers ...................................... 153
What Is a ‘Peak’ .................................................... 156
Marker Functions ................................................ 157
SA Noise Marker .................................................. 157
SA Band Power Marker ...................................... 158
SA Frequency Counter at Marker ..................... 158
All about Limit Lines .......................................... 158
Relative Limit Lines ............................................ 159
Build From Trace ................................................. 160
Limit Options........................................................ 160
How to Save and Recall Limits .......................... 161
All about Trace Math ........................................... 161
About Math Operations ...................................... 162
All about Markers
Markers move along the X-axis range of the measurement trace to provide a
numerical readout of each measured data point. Markers also allow you to search
for specific Y-axis values.
A trace can contain up to six markers.
The marker readout on the FieldFox screen displays X and Y-axis information for
the current active marker ONLY.
A Marker Table can be displayed that allows you to simultaneously view X and Y-
axis information for all markers.
Markers can be used in CAT, SA, and NA Modes.
How to create Markers
Press Marker.
Then Markers 1...6 to select a marker to activate.
Then Normal to activate that marker. A marker is created on the trace in the
middle of the X-axis. That marker is now active.