Wiegand Input Data Order: set the Wiegand input data sequence between
“ Normal” and “Reversed” if you select “ Reversed” then the input card
number will be reversed and vice versa.
Wiegand Output Data Order: set the Wiegand output data sequence
between “ Normal” and “Reversed” if you select “ Reversed” then the
input card number will be reversed and vice versa.
Wiegand Output CRC: tick to enable the parity check function to ensure
that signal-based data can be transmitted correctly according to the
established data transmission format.
You can configure the Wiegand output mode if needed. The output occurs
when you press the PIN code on the device.
Parameter Set-up:
PIN: select “Disabled” if you want to disable the function. Select “4 bits
per digit” if you want to output the PIN code by four continuous bits as a
set. Select “8 bits per digit” if you want to output the PIN code by eight
continuous bits as a set.
21.2.Integration with Milestone
If you want to integrate the door phone with the Milestone VMS system for
monitoring purpose. You need to enable the Milestone integration first before
you can integrate them. You can navigate to Intercom > ONVIF > Advanced
Setting.