12. Door Access Control Configuration
12.1.Relay Switch Setting
You can configure the relay switch(es) for the door access on the web
Intercom > Relay > Relay interface.
Parameter Set-up:
Relay ID: you are allowed to set up three relay switches in total for the
door access control ( R29Z/R29ZL has only 1 relay).
Type: if Default state is selected, the Relay Status shows Low which
means the door is closed, the Relay Status shows which means the door
is opened. If Invert State is selected, the Relay Status hows High which
means the door is closed, and Low means the door is opened.
Mode: there are two modes Monostable and Bistable. If Monostable is
selected, the relay status will be automatically reset within the relay delay
time after the relay is triggered. If Bistable is selected, relay status will be
reset after the relay is triggered again.