MM-400A
8. Operation Screens
8-89
(1) MEASUREMENT MODE
Select the displacement measurement system from the following:
REFERENCE: The displacement is reset (0 mm) at the start of current or the
external input signal DIST TRIGGERand the measurement is started.
In DIST INITIAL, DIST PULSE1, DIST PULSE2, and DIST FINAL, the
moving amount from the position set to 0 mm at the start of current or the
external input signal DIST TRIGGERis measured.
The displacement level 1 to 3 outputs “DIST LEV1 to 3” are output when
moving from the position set to 0 mm at the start of current or the external
input signal DIST TRIGGERis output.
In the level output, signals are output when “measured value ≥ level output
value” is satisfied in plus (+) setting and “measured value ≤ level output value”
is satisfied in minus (-) setting.
When setting TRIGGER to CURRENT, INITIAL MEASUREMENT to
CURRENT START, MEAS AFTER PULSE to CURRENT START”, and
FINAL MEASUREMENT to DELAY TIMEto measure DIST INITIAL, DIST
PULSE1” and DIST FINAL.
Performs a reset (0 mm) of displacement at the timing of WE1 current start
(A).
Measures the position of 0 mm as DIST INITIAL(B) at the timing of WE1
current start (A). (To measure DIST INITIAL, use any of ABSOLUTE1 to
ABSOLUTE4.)
Measures the moving amount from the position set to 0 mm at the start of
current as DIST PULSE1” (D) at the timing of WE2 current start (C).
Measures the moving amount from the position set to 0 mm at the start of
current as DIST FINAL(F) at the timing of the elapse of the delay time (E).
ABSOLUTE1: The position of 0 mm is set in advance and the displacement is
measured.
In DIST INITIAL, DIST PULSE1, DIST PULSE2, and DIST FINAL, the
moving amount from the position set to 0 mm set in advance is measured.
-
+
0 B
F
D
C
A
E
WE3CO2WE2CO1WE1
Displacement
Welding current
Judgment output
F
D
C
A
-
+
0 B
E
WE3CO2WE2CO1WE1
Displacement
Welding current
Judgment output

Table of Contents