MM-400A
12. Data Communication
12-19
Communication example
Measurement history data of ID NO. 01 and SCH.# 1 is transmitted from the MM-400A.
“MM-400A → Host computer”
!01001S07:17/01/17_06:10:16,02,L,01.46kA,00,L,01.78kA,05,
G,00.0V,03,G,00.0V,09,G,0008.0CYC,19,G,0810N,34,-,0,34,
-,0,34,-,0,34,-,0,0,G,G,L,1,G,G,L[CR][LF]
!01001S07:17/01/17_06:10:09,02,L,01.46kA,00,L,01.79kA,05,
G,00.0V,03,G,00.0V,09,G,0008.0CYC,19,G,0810N,34,-,0,34
,-,0,34,-,0,34,-,0,0,G,G,L,1,G,G,L[CR][LF]
!01001S06:17/01/17_04:24:31,02,G,00.00kA,00,G,01.76kA,05,
G,00.0V,03,G,00.0V,09,G,0008.0CYC,19,G,0812N,34,-,0,34,
-,0,34,-,0,34,-,0,0,G,G,G,1,G,G,G[CR][LF]
!01001S06:17/01/17_04:24:00,02,G,01.45kA,00,G,01.76kA,05,
G,00.0V,03,G,00.0V,09,G,0008.0CYC,19,G,0815N,34,-,0,34,
-,0,34,-,0,34,-,0,0,G,G,G,1,G,G,G[CR][LF]
!01001S06:17/01/17_03:55:52,02,G,01.40kA,00,G,01.70kA,05,
G,00.0V,03,G,00.0V,09,G,0008.0CYC,19,G,0811N,34,-,0,34
,-,0,34,-,0,34,-,0,0,G,G,G,1,G,G,G[CR][LF]
Error history data of ID NO. 01 is transmitted from the MM-400A.
“MM-400A → Host computer”
!01001S07:17/01/17_06:10:16,02,L,01.46kA,00,L,01.78kA,05,
G,00.0V,03,G,00.0V,09,G,0008.0CYC,19,G,0810N,34,-,0,34,
-,0,34,-,0,34,-,0,0,G,G,L,1,G,G,L[CR][LF]
!01001S07:17/01/17_06:10:09,02,L,01.46kA,00,L,01.79kA,05,
G,00.0V,03,G,00.0V,09,G,0008.0CYC,19,G,0810N,34,-,0,34,
-,0,34,-,0,34,-,0,0,G,G,L,1,G,G,L[CR][LF]
(Note) A space falls into “_”.