MM-400A
12. Data Communication
12-34
Item Display Range Length
51 Delimiter , 1
52 TRIGGER LEVEL 02.0% 02.0 to 99.9% 5
53 Delimiter , 1
54 INITIAL
MEASUREMENT
0 0: CURRENT START
1: EXTERNAL INPUT
1
FORCE
55 OFFSET +00000N__ 00490 to 09806N__
049.0 to 980.6N__
04.90 to 98.06N__
00050 to 01000kgf
005.0 to 100.0kgf
00.50 to 10.00kgf
00110 to 02204lbf
011.0 to 220.4lbf
01.10 to 22.04lbf
9
56 Return code [CR] (0x0d) 1
57 Feed code [LF] (0x0a) 1
* A space falls into “_” for digit matching.
Output data common to all schedules (SCH.# 000)
Item Display Range Length
1 Start code ! 1
2 ID NO. 01 01 to 31 2
3 SCH.# 000 000 3
4 Screen code S 1
5 Item No. 13 2
6 Delimiter : 1
8 “INITIAL MEASUREMENT” to 55 “OFFSET” in EXTEND SETUP Writing request data
for schedule
54 Return code [CR] (0x0d) 1
55 Feed code [LF] (0x0a) 1