MM-400A
12. Data Communication
12-44
6) SYSTEM SETUP [Item No. 14]
Writing request data (SCH.# 000)
1 Start code # 1
2 ID NO. 01 01 to 31 2
3 Write code W 1
4 SCH.# 000 000 3
5 Screen code S 1
6 Item No. 14 2
7 Delimiter : 1
8 MODE 0 0: NORMAL
1: SEAM
2: NORMAL TRACE
3: SINGLE TRACE
1
9 Delimiter , 1
10 LANGUAGE 0 0: ENGLISH
1: GERMAN
2: FRENCH
3: SPANISH
4: JAPANESE
5: KOREAN
6: CHINESE
1
11 Delimiter , 1
12 WELD COUNTER PRESET 000000 000000 to 999999 6
13 Delimiter , 1
14 GOOD COUNTER PRESET 000000 000000 to 999999 6
15 Delimiter , 1
16 BRIGHTNESS 01 01 to 10 2
17 Delimiter , 1
18 BRIGHTNESS 0 0: OFF
1: AUTO
1
19 Delimiter , 1
CURRENT
20 SAMPLING INTERVAL 0 0: 20us
1: 50us
2: 100us
3: 200us
1
21 Delimiter , 1
22 CONVERSION COEFFICIENT 100.0mV/kA 100.0 to 250.0mV/kA 10
23 Delimiter , 1
FORCE / EXTERNAL
24 SAMPLING INTERVAL 0 0: 100us
1: 200us
2: 500us
1
25 Return code [CR] (0x0d) 1