EasyManua.ls Logo

Amada WELD CHECKER MM-400A - Page 265

Amada WELD CHECKER MM-400A
328 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MM-400A
12. Data Communication
12-44
6) SYSTEM SETUP [Item No. 14]
Writing request data (SCH.# 000)
Item
Display
Range
Length
1 Start code # 1
2 ID NO. 01 01 to 31 2
3 Write code W 1
4 SCH.# 000 000 3
5 Screen code S 1
6 Item No. 14 2
7 Delimiter : 1
8 MODE 0 0: NORMAL
1: SEAM
2: NORMAL TRACE
3: SINGLE TRACE
1
9 Delimiter , 1
10 LANGUAGE 0 0: ENGLISH
1: GERMAN
2: FRENCH
3: SPANISH
4: JAPANESE
5: KOREAN
6: CHINESE
1
11 Delimiter , 1
12 WELD COUNTER PRESET 000000 000000 to 999999 6
13 Delimiter , 1
14 GOOD COUNTER PRESET 000000 000000 to 999999 6
15 Delimiter , 1
16 BRIGHTNESS 01 01 to 10 2
17 Delimiter , 1
18 BRIGHTNESS 0 0: OFF
1: AUTO
1
19 Delimiter , 1
CURRENT
20 SAMPLING INTERVAL 0 0: 20us
1: 50us
2: 100us
3: 200us
1
21 Delimiter , 1
22 CONVERSION COEFFICIENT 100.0mV/kA 100.0 to 250.0mV/kA 10
23 Delimiter , 1
FORCE / EXTERNAL
24 SAMPLING INTERVAL 0 0: 100us
1: 200us
2: 500us
1
25 Return code [CR] (0x0d) 1

Table of Contents