MM-400A
12. Data Communication
12-52
Item Display Range Length
85 Output 11 -2 62 (External output 1 to 12 code table) 2
86 Delimiter , 1
87 Output 11 -3 62 (External output 1 to 12 code table) 2
88 Delimiter , 1
89 Output 12 -1 62 (External output 1 to 12 code table) 2
90 Delimiter , 1
91 Output 12 -2 62 (External output 1 to 12 code table) 2
92 Delimiter , 1
93 Output 12 -3 62 (External output 1 to 12 code table) 2
94 Delimiter , 1
95 PARITY 0 0: OFF
1: ON
1
96 Delimiter , 1
97 INPUT DELAY
TIME
0 0: 1ms
1: 10ms
1
98 Delimiter , 1
99 NG OUTPUT
MODE
0 0: NORMALLY CLOSED
1: NORMALLY OPEN
1
100 Delimiter , 1
101 OUTPUT TIME 0 0: 10ms
1: 100ms
2: HOLD
1
102 Delimiter , 1
103 LEVEL OUTPUT 0 0: LEVEL
1: PULSE
1
104 Return code [CR] (0x0d) 1
105 Feed code [LF] (0x0a) 1