EasyManua.ls Logo

Amada WELD CHECKER MM-400A - Page 273

Amada WELD CHECKER MM-400A
328 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MM-400A
12. Data Communication
12-52
Item Display Range Length
85 Output 11 -2 62 (External output 1 to 12 code table) 2
86 Delimiter , 1
87 Output 11 -3 62 (External output 1 to 12 code table) 2
88 Delimiter , 1
89 Output 12 -1 62 (External output 1 to 12 code table) 2
90 Delimiter , 1
91 Output 12 -2 62 (External output 1 to 12 code table) 2
92 Delimiter , 1
93 Output 12 -3 62 (External output 1 to 12 code table) 2
94 Delimiter , 1
95 PARITY 0 0: OFF
1: ON
1
96 Delimiter , 1
97 INPUT DELAY
TIME
0 0: 1ms
1: 10ms
1
98 Delimiter , 1
99 NG OUTPUT
MODE
0 0: NORMALLY CLOSED
1: NORMALLY OPEN
1
100 Delimiter , 1
101 OUTPUT TIME 0 0: 10ms
1: 100ms
2: HOLD
1
102 Delimiter , 1
103 LEVEL OUTPUT 0 0: LEVEL
1: PULSE
1
104 Return code [CR] (0x0d) 1
105 Feed code [LF] (0x0a) 1

Table of Contents