7-14 Replacing Hand Strap – 3-61470 Assembly Removal and Replacement, MS203xC
7-24 PN: 10580-00307 Rev. D MS20xxC MM
7-14 Replacing Hand Strap – 3-61470
This procedure provides instructions for replacing the right side Hand Strap using existing hardware. The case
does not need to be opened for this procedure.
Part Numbers
• 3-61470 – Hand Strap
Procedure
1. Place the instrument face up on a protected work surface orientated with the top Connector Panel toward
the right.
2. Using the flat blade screwdriver, remove the two M3 Slotted Screws holding the two Plastic Ring Holders
to the case.
3. Orient the strap so that the word “Anritsu” reads correctly.
4. Capture one Handle End Ring with the Ring Holder and screw into place.
5. Making sure that the strap is not twisted, capture the remaining ring with the Ring Holder and screw it
into place.