9.2 Command Set 69
Broadcast Mode - NMEA183ZDA
Command: 1,nB
1,nB configures the clock to broadcast the National Marine Electronics Association Standard
(NMEA - 0183) to broadcast ZDA format from the main RS-232C port, where n = the update rate
in seconds from 1 to 9999. ZDA, time and date, includes the UTC day, month, year, and local time
zone.
Response: $–ZDA,hhmmss.ss,dd,mm,yyyy,±xx,xx*cs
C
Where: ZDA = Time and date
hhmmss.ss = Time in UTC
dd = Day, 01 to 31
mm = Month, 01 to 12
yyyy = Year
±xx,xx = Local zone description, 00 to ±13 hours and minutes
*cs = checksum
9.2.2 Event Mode Commands
Return Specific Event
Command: nnnA
nnnA sets the event buffer read index to a specific event number (001 to 500), and returns that
event information in either Local or UTC time format depending on how the command, nTA is
configured.
Response: LCL mm/dd/yyyy hh:mm:ss.sssssss nnnL
C
or
UTC mm/dd/yyyy hh:mm:ss.sssssss nnnU
C
Format: nnn= Event–Buffer Read Index Number
U = UTC Time
L = Local Time
Set Event Channel Time
Command: nTA
nTA sets the time source as either Local or UTC, where n = 0 sets the event time to UTC and n
= 1 sets the event time to Local.
Response:
C
Set Channel Deviation
Command: AD
AD sets channel A to the 1-PPS deviation mode.
Response:
C

Table of Contents

Other manuals for Arbiter Systems 1084A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Arbiter Systems 1084A and is the answer not in the manual?

Arbiter Systems 1084A Specifications

General IconGeneral
BrandArbiter Systems
Model1084A
CategoryClock
LanguageEnglish