Retrofit of the I/O module pneumatic panel and circuit
To support the i2000SR, the pneumatic panel at the IOM must
continuously supply air to the i2000SR IM when the APS workcell
is shutdown and power is OFF. To provide this source of air, the
IOM pneumatic panel has a manifold with a bank of manual
valves.
The following steps are required only if the i2000SR IM is
installed on a Workcell with original IOM pneumatic panel (P/N
510.500.001) (See
Figure 68
)
At the APS, shutdown the system.
At the site air supply distribution to the Accelerator APS
turn OFF the air supply valve.
Remove the pneumatic panel (P/N 510.500.001) from the
I/O Module.
Figure 68 – IOM Pneumatic Panel (old style)
Item
Function Item Function
1 Air supply line
4 To IOM Robot
2 Output to tank 5 From IOM Robot to Festo
Sensor
3 From tank 6 Control Interface
Replace with the pneumatic panel (P/N 510.500.002)
(203848).