Version 6.6 385 MP-11x & MP-124
User's Manual 37. Syslog and Debug Recordings
To configure logging filtering rules:
1. Open the Logging Filters Table page (Configuration tab > System menu > Logging
> Logging Filters Table).
2. Click the Add button; the Add Record dialog box appears:
Figure 37-2: Logging Filters Table - Add Record Dialog Box
3. Configure the logging filter, as required. See the table below for a description of the
parameters.
4. Click Submit to save your changes.
Notes:
To configure the Syslog debug level, use the 'Debug Level' parameter
(see 'Configuring Syslog' on page 383).
The Logging Filters table can also be configured using the table ini file
parameter, LoggingFilters.
Table 37-5: Logging Filters Table Parameters Description
Parameter Description
Type
[LoggingFilters_Type]
Defines the filter criteria.
[1] Any (Default)
[3] Trunk Group ID
[5] FXS or FXO
[6] Tel to IP = Specific Tel-to-IP routing rule listed in the
Outbound IP Routing table.
[7] IP to Tel = Specific IP-to-Tel routing rule listed in the
Inbound IP Routing table.
[8] IP Group
[12] User = Specific user, defined by username or user@host.
Value
[LoggingFilters_Value]
Defines the value of the selected filtering type. This can be a single
value, a range separated by a dash or comma, or 'Any' (except for
Trunks and FXO/FXS which can be module/port or port).
Syslog
[LoggingFilters_Syslog]
Enables Syslog messages for the defined logging filter:
[0] Disable (default)
[1] Enable

Table of Contents