User's Manual 480 Document #: LTRT-65417
MP-11x & MP-124
combined FXS / FXO devices, the FXS ports are provided with a
lifeline by their corresponding FXO ports which are connected to
the PSTN / PBX (i.e., FXO Port 5 provides a lifeline for FXS Port 1,
FXO Port 6 provides a lifeline for FXS Port 2, and so on).
ï‚§ [0] = (Default) Lifeline is activated upon power outage.
ï‚§ [1] = Lifeline is activated upon power outage or when the link is
down (physically disconnected).
ï‚§ [2] = Lifeline is activated upon a power outage, when the link is
down (physically disconnected), or upon network failure (logical
link disconnected).
Notes:
ï‚§ For this parameter to take effect, a device reset is required.
ï‚§ This parameter is applicable only to FXS interfaces.
ï‚§ To enable Lifeline upon a network failure, the LAN watch dog
must be activated (i.e., set the parameter EnableLANWatchDog
to 1).
ï‚§ For information on Lifeline cabling, refer to the Installation
Manual.
Web: Delay After Reset [sec]
[GWAppDelayTime]
Defines the time interval (in seconds) that the device's operation is
delayed after a reset.
The valid range is 0 to 45. The default value is 7 seconds.
Note: This feature
helps overcome connection problems caused by
some LAN routers or IP configuration parameters' modifications by
a DHCP server.
[EnableAutoRAITransmitBER]
Enables the device to send a remote alarm indication (RAI) when
the bit error rate (BER) is greater than 0.001.
ï‚§ [0] Disable (default)
ï‚§ [1] Enable
43.3.2 SIP Test Call Parameters
The SIP Signaling Test Call parameters are described in the table below.
Table 43-16: SIP Test Call Parameters
Parameter Description
[TestCallDtmfString]
Defines the DTMF tone that is played for answered test calls (incoming
and outgoing).
The DTMF string can be up to 15 strings. The default is "3212333". An
empty string means that no DTMF is played.
Web: Test Call ID
[TestCallID]
Defines the test call prefix number (ID) of the simulated phone on the
device. Incoming calls received with this called prefix number are
identified as test calls.
This can be any string of up to 15 characters. By default, no number is
defined.
Notes:
ï‚§ This parameter is only for testing incoming calls destined to this
prefix number.
ï‚§ This feature is applicable to all applications (GW/IP-to-IP and SBC).