4. In the Internet Protocol (TCP/IPv4) Properties dialog, select Use the following IP address
and make sure
that the IP address is 192.168.0.2, and the subnet mask is 255.255.255.0.
Sensor Setup for Ethernet Communications
1.
Go to Main Menu > System > Communications > Ethernet I/O and make sure that the sensor is configured
as shown below.
2.
To enable the command channel over Ethernet:
a. Go to Main Menu > System > Communications > Command Channel > Connection, and select
Ethernet [IP Port # 32000].
b.
Configure the field and end-of-frame delimiters. Go to Main Menu > System > Communications >
Command Channel > Delimiters.
iVu Plus TG Gen2 Image Sensor
www.bannerengineering.com - Tel: 763.544.3164 81