Valid end-of-frame delimiters are: <comma>, <colon>, <semicolon>, <CR>, <CR><LF>, <LF><CR>, or
<ETX>.
c.
Verify that the iVu receives and transmits data correctly.
3. To enable Data Export over Ethernet:
a. Go to Main Menu > System > Communications > Data Export > Connection and select Serial I/O
from the drop-down.
b.
Go to Main Menu > System > Communications > Data Export > Data To Export and select the
inspection data to export.
c.
Go to Main Menu > System > Communications > Data Export > Output Format and select the Start
String, Delimiter, and End String.
iVu Plus TG Gen2 Image Sensor
82 www.bannerengineering.com - Tel: 763.544.3164