DECS-200 BESTCOMS Software 5-29
System Status, Operating Mode.
Enables a data log report to be triggered when power factor control is
active or var control is active. Selecting “No Trigger” disables an operating mode trigger.
System Status, Load Compensation.
Enables a data log report to be triggered when droop compensation
is active or inactive. Selecting “No Trigger” disables a load compensation trigger.
System Status, Limiter Mode.
Enables a data log report to be triggered when the underexcitation limiter,
overexcitation limiter, or stator current limiter are active. Additionally, a data log report can be triggered
when two of the limiters are active. The available limiter mode selections are listed below:
No Trigger (disables a limiter mode trigger)
OEL (overexcitation limiter active)
Off (no limiters active)
SCL (stator current limiter active)
SCL, OEL (stator current limiter and overexcitation limiter active)
SCL, UEL (stator current limiter and underexcitation limiter active)
UEL (underexcitation limiter active)
UEL, OEL (underexcitation limiter and overexcitation limiter active)
System Status, Voltage Matching.
Enables a data log report to be triggered when voltage matching is
enabled (On) or disabled (Off). Selecting No Trigger disables a voltage matching trigger.
System Status, Auto Tracking.
Enables a data log report to be triggered when the DECS-200 is
functioning as the primary controller or the secondary controller in a redundant DECS-200 system.
Selecting No Trigger disables an auto-tracking trigger.
Level Triggers/ Logged Parameters
The Level Triggers/Logged Parameters tab (Figure 5-33) consists of a list of parameters that can be
selected to trigger a data log report. Up to six parameters can be selected as triggers. Each parameter
has Level Trigger Enable buttons that are used to trigger a data log when the parameter increases above
the upper threshold setting, decreases below the lower threshold setting, or either increases above or
decreases below the upper or lower threshold setting. The available parameters that can be selected to
trigger a data log report are listed in Table 5-2.
Figure 5-33. Data Log Screen, Level Triggers/Logged Parameters