6 Troubleshooting
Page 107
6 Troubleshooting
Problem: The unit cannot be switched on.
• Cause: Power cord not connected properly. Mains power not available. Main power fuses defect.
• Solution: Check the power cords and the mains power supply. Check the main power fuses at the back
panel of the amplifier.
Problem: Amplifier is switched on, audio signal supplied but LED SIGNAL doesn’t illuminate.
• Cause: Audio input cable defect or not properly connected.
• Solution: Check the audio signal cables and the signal source.
Problem: SIGNAL LED is on, but no sound.
• Cause: Speaker cables are not connected properly, or loudspeaker defect. Speaker cables connected to
the wrong channel, or polarity in SPEAKON connector not according to the norm.
• Solution: Check the speaker cables and the loudspeakers.
Problem: No communication to the control computer.
• Cause: Wiring incorrect.
• Solution: Check wiring in general, check polarity of the data cables, check additional ground connec-
tion for the data cables between devices.
Problem: No communication to the control computer, or to a single amplifier.
• Cause: Invalid address is set.
• Solution: Check DIP-Switches on the back panel of the SXL, address 0 to 15 possible in one system,
same address in one system will cause failure.
c
2016 Bittner Audio Int. GmbH