Fault Possible causes Fault elimination
Insufficient or no liquid is dis-
charged from the outlet of the sepa-
rating and conveying unit
Liquid phase outlet is closed or
blocked
Open the shut-off devices
Clean the drainpipe
Inlet pressure is too low, the substrate
does not reach the outlet
Increase the inlet pressure
DS content of the substrate too high
Only use the Bioselect as
intended, i.e. for digestate and
liquid manure in accordance with
Ä
Chapter 2.3 “Proper use”
on page 15.
The outlet connection leaks
Tighten the screws on the flange
connection cross-wise with uni-
form strength
Check/replace the seal
Check the pipes for damage and
rectify, if necessary
Rule out leaks in other compo-
nents
Fault Possible causes Fault elimination
Liquid escapes from the safety
opening
Temperature-related expansion with
too much fluid in intermediate
chamber
Drain some of the quench fluid
out of the intermediate chamber
Shaft seal on product side damaged
Replace the mechanical seal
NOTE!
Contact Börger GmbH if there are other kinds of malfunctions or
any other causes for malfunctions.
Operation
BA-RC40_EN, 17.01.2024 www.boerger.de / www.boerger.com 107