Fault Possible causes Fault elimination
Insufficient or no liquid is dis-
charged from the outlet of the sepa-
rating and conveying unit
Liquid phase outlet is closed or
blocked
— Open the shut-off devices
— Clean the drainpipe
Inlet pressure is too low, the substrate
does not reach the outlet
— Increase the inlet pressure
DS content of the substrate too high
— Only use the Bioselect as
intended, i.e. for digestate and
liquid manure in accordance with
Ä
Chapter 2.3 “Proper use”
on page 15.
The outlet connection leaks
— Tighten the screws on the flange
connection cross-wise with uni-
form strength
— Check/replace the seal
— Check the pipes for damage and
rectify, if necessary
— Rule out leaks in other compo-
nents
Fault Possible causes Fault elimination
Liquid escapes from the safety
opening
Temperature-related expansion with
too much fluid in intermediate
chamber
— Drain some of the quench fluid
out of the intermediate chamber
Shaft seal on product side damaged
— Replace the mechanical seal
NOTE!
Contact Börger GmbH if there are other kinds of malfunctions or
any other causes for malfunctions.