6.2 Maintenance and inspection
6.2.1 Maintenance and inspection plan
NOTICE!
Risk of material damage due to improper maintenance!
Also observe the maintenance intervals detailed in the oper-
ating manuals for the drive gear unit, motor etc., which are
included in the appendix.
Prepare a maintenance schedule adapted to the operating
conditions.
NOTE!
Replacement of the Multi Disc plate
Check the wear limit for the Multi Disc plate!
The peeling tabs of the Multi Disc plate should have a residual
height of at least 2.5 mm!
Otherwise, replace the Multi Disc plate!
NOTE!
Maintenance intervals
The following intervals are guidelines. These intervals can be sig-
nificantly reduced depending on the operating conditions.
when necessary
Checking the outer surfaces for dust deposits and dirt
If necessary, clean the outer surfaces
Ä
Chapter 6.1 “Machine care” on page 111
Checking the wedge wire screen for clogging/contamination
If necessary, clean the wedge wire screen
Ä
Chapter 6.1.3 “Internal cleaning” on page 116
Maintenance and repairs