daily
Audible check for smooth running
— In the event of a malfunction: take appropriate measures
Ä
Chapter 5.6 “Malfunctions” on page 103
Visual check for leaks
— Replace the seals, if necessary
Ä
Chapter 5.6 “Malfunctions” on page 103
Checking the function and quantity/quality of the thick matter
— Adjust operating parameters
Ä
Chapter 5.6 “Malfunctions” on page 103
— Replace damaged parts, if necessary
Ä
Chapter 5.6 “Malfunctions” on page 103
Checking the horizontal alignment of the Börger machine
— Correct alignment, if necessary
weekly
Clean and lubricate the adjustment mechanism and the bearing as described in
Ä
Chapter 6.2.3 “Lubricating
the adjustment mechanism and the bearing” on page 127
— Lubricate the adjustment mechanism and the bearing every 50 operating hours, at the latest after one week, using
a suitable multi-purpose grease as detailed in the lubricant list.
monthly
Checking the level of the quench fluid in the intermediate chamber
— Refill, if necessary
Checking the oil level of the gear unit according to the operating manual of the gear unit manufacturer
— Refill, if necessary, according to operating manual of gear unit manufacturer
quarterly
Checking the Börger machine and attachment parts for tight fit and possible damage
— Tighten any loosened parts
— Replace damaged parts
Checking all safety notes, warnings and operating instructions
— If necessary, replace damaged signs or stickers immediately
Maintenance and repairs
BA-RC40_EN, 17.01.2024 www.boerger.de / www.boerger.com 121