EasyManua.ls Logo

Borger Bioselect RC 40 - Page 121

Default Icon
199 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
daily
Audible check for smooth running
In the event of a malfunction: take appropriate measures
Ä
Chapter 5.6 “Malfunctions” on page 103
Visual check for leaks
Replace the seals, if necessary
Ä
Chapter 5.6 “Malfunctions” on page 103
Checking the function and quantity/quality of the thick matter
Adjust operating parameters
Ä
Chapter 5.6 “Malfunctions” on page 103
Replace damaged parts, if necessary
Ä
Chapter 5.6 “Malfunctions” on page 103
Checking the horizontal alignment of the Börger machine
Correct alignment, if necessary
weekly
Clean and lubricate the adjustment mechanism and the bearing as described in
Ä
Chapter 6.2.3 “Lubricating
the adjustment mechanism and the bearing” on page 127
Lubricate the adjustment mechanism and the bearing every 50 operating hours, at the latest after one week, using
a suitable multi-purpose grease as detailed in the lubricant list.
monthly
Checking the level of the quench fluid in the intermediate chamber
Refill, if necessary
Checking the oil level of the gear unit according to the operating manual of the gear unit manufacturer
Refill, if necessary, according to operating manual of gear unit manufacturer
quarterly
Checking the Börger machine and attachment parts for tight fit and possible damage
Tighten any loosened parts
Replace damaged parts
Checking all safety notes, warnings and operating instructions
If necessary, replace damaged signs or stickers immediately
Maintenance and repairs
BA-RC40_EN, 17.01.2024 www.boerger.de / www.boerger.com 121

Table of Contents