Loading...
biannually
Checking the quality of the quench fluid
Replace the quench fluid, if necessary
Ä
Chapter 6.2.2 “Lubricant fill level and changing the lubricants”
on page 123
Replace seals, if necessary
Ä
Chapter 6.3.3 “Replacing the mechanical seal” on page 137
Belt drive: Checking the belt tension
Correct belt tension, if necessary
Belt drive: Visual check for cracks and porous areas
Replace belt, if necessary (always replace the belts completely and with belts which consist of a single piece, have
discharging properties and are of the same set)
yearly
Checking the electrical system and control unit for integrity and proper function
Changing the lubricants
NOTE!
Observe the operating conditions!
The oil change intervals apply to normal operating condi-
tions.
Change the lubricants after approximately 8000 operating
hours or after one year, whichever occurs first.
Extreme operating conditions (higher operating temperatures,
high air humidity, aggressive environment and frequent
changes in operating temperature) shorten the oil change
intervals.
NOTE!
Changing the lubricant
Observe the detailed information and instructions on changing
the lubricant as described in the lubricant list and in the data
sheet regarding the lubricants used.
Maintenance and repairs
BA-RC40_EN, 17.01.2024www.boerger.de / www.boerger.com122