NOTICE!
Risk of damage to the gear unit when the intermediate
chamber is closed tightly!
When the vent hole is closed tightly or has become blocked,
emerging medium from the working chamber cannot escape
through the intermediate chamber and will penetrate the gear unit
if the mechanical seal is defective. This could damage the gear
unit.
The safety opening in the intermediate chamber is used for
monitoring the integrity of the mechanical seal, and must not
be closed.
Overflowing of the intermediate chamber indicates a seal
malfunction.
3.1.7 Maintenance openings
WARNING!
Risk of fatal injury if maintenance openings are opened
during operation!
If maintenance openings are opened during operation, objects
and materials can be ejected and sources of danger become
accessible. This may lead to severe injury or death.
Only open the maintenance openings with the machine at
standstill and the power supply switched off and secured
against uncontrolled reactivation.
After completion of the work close the maintenance openings
and reinstall all fastening elements.
Fiber accumulation and dirt can be removed through the mainte-
nance opening (8).