6.3.3 Replacing the mechanical seal
NOTICE!
Risk of material damage due to incorrect handling of
mechanical seals!
Make sure not to damage the sealing surfaces of the new seal
faces.
The sealing surfaces must be clean and should not be
scratched.
NOTICE!
Risk of loss of seal function due to oil/grease on the O-rings
of mechanical seals!
Material damage resulting from loss of seal function
The O-rings of a mechanical seal must be installed without oil
or grease.
NOTE!
Spray cleaner (degreaser)
Generally, the seal faces equipped with O-rings can be inserted
dry.
In order to ensure that they are free of grease and to aid
insertion, the O-rings can be sprayed lightly, depending on
their resistance, with a quickly-volatilizing spray cleaner
(degreaser) that leaves no residue.
Maintenance and repairs
BA-RC40_EN, 17.01.2024 www.boerger.de / www.boerger.com 137