9.10 Technical data (maintenance)
9.10.1 Lubricants - fill levels
NOTE!
Lubricant list and data sheet!
Observe the detailed information and instructions on changing
the lubricant as described in the lubricant list and in the data
sheet regarding the lubricants used.
NOTE!
Fill level in the intermediate chamber!
Check the fill level in the intermediate chamber having regard
to the information detailed under lubricant fill level and changing
the lubricants.
Ä
Chapter 6.2.2 “Lubricant fill level and changing
the lubricants” on page 123
Check whether the delivered quench fluid (see enclosed
data sheet) is suitable or whether an alternative fluid must be
used in order to observe environmental protection regulations,
or for biological or other reasons. This must be compatible
with the medium, and must not adversely affect the O-rings of
the mechanical seals. Consult Börger GmbH regarding this, if
necessary.
Design
(mounting position)
Intermediate chamber
M1
(upright)
Up to the center of or covering the shaft
Fill quantity
Design
(mounting position)
Intermediate chamber
approx. [l] approx. [gal]
M1
(upright)
0.8 0.21
Optimum fill level
RC 40