3.1.9 Pipe connections on inlet and outlet
Inlet/feed
The feed unit of the separator has two short, straight pipe con-
nectors with a 6'' square flange each, whereby the unused con-
nector is closed with a blind flange.
Outlet/drain
The standard version of the separator is equipped with a 6"
square flange, e.g. to connect the appropriate valve (slurry
valve, brass double four-bolt flange valve).
Options
The inlet and outlet can be equipped with the same or different
pipe connectors. Pipe connectors are available with a variety of
connections, for example:
DIN EN flange
ANSI/ASME flange
Quarter turn coupling
Quick-release coupling, e.g. Perrot, female adapter (optional
male)
Dairy screw connections, and others
The pipe connectors can be equipped with optional additional fit-
tings, e.g. screw sockets G½" or G 1" or screw sockets with NPT
threads, for the connection of pressure gauges, shut-off devices or
breather systems.