Be sure to read and follow all instructions:
on safety,
on operation and control,
on installation, repairs and maintenance.
Ä
Chapter 2.12
“Safety instructions for maintenance and rectifying malfunc-
tions” on page 37
Shut down the Börger machine and downstream and upstream
system components.
Ä
Chapter 5.4 “Downtimes” on page 100
Secure the Börger machine against unauthorized or uncon-
trolled reactivation.
Ä
Chapter 2.7 “Securing the machine
against restart” on page 26
Relieve the pressure in the Börger machine.
Ä
Chapter 6.1.2
“Pressure relief” on page 114
1. Remove the required flange connections and maintenance
openings to get to the working chamber of the Börger
machine.
2. Thoroughly clean the rotating parts and the working chamber
of the machine from deposits and contamination.
3. Thoroughly clean all parts before reinstalling removed parts.
4. Check all removed parts for wear and only reuse them if they
are undamaged.
5. Only replace worn components, seals, screws, nuts etc., but
especially the wetted parts, with original spare parts.
6. Reassemble the flange connections and maintenance open-
ings that have been loosened previously.
NOTE!
Cleaning the adjustment mechanism
Clean and lubricate the adjustment mechanism at regular inter-
vals to prevent the Multi Disc from blocking.
Ä
Chapter 6.2.1
“Maintenance and inspection plan” on page 120
Observe
Ä
Chapter 2.12 “Safety instructions for maintenance
and rectifying malfunctions” on page 37 and switch off the
feed or close the valve of the feed. Switch off the Bioselect.
Lubricate the adjustment mechanism as described in
Ä
Chapter 6.2.3 “Lubricating the adjustment mechanism and
the bearing” on page 127.
Maintenance and repairs
BA-RC40_EN, 17.01.2024www.boerger.de / www.boerger.com118

Table of Contents