Always adhere to the following storage conditions for the
Börger machine:
— The storage room must be evenly ventilated and free of dust
and vibrations
— The relative humidity must be below 65% and the temperature
between 15 °C and 25 °C (59 °F and 77 °F)
— Avoid exposure to direct heat sources (sunlight, heating)
1. Repair any damage to the external coating, galvanized com-
ponents and corrosion protection on bare metal parts caused
by external influences.
2. Protect the Börger machine from cold, particularly from frost,
as well as from moisture, contamination and mechanical influ-
ences. Close the inlet and outlet connections in particular
(flange, coupling etc.), plus any other openings to the interior
with covers impermeable to moisture.
3. Before commissioning / recommissioning at a later date,
remove all protective covers and anti-corrosion coatings.
If the device was stored for two years or more, or if the
storage conditions detailed above could not be met:
— Read and follow the safety instructions detailed in
Ä
Chapter
2.12 “Safety instructions for maintenance and rectifying mal-
functions” on page 37.
— To the extent necessary, amply secure the surrounding area
when performing maintenance. Cordon off the working area
with a red and white safety chain and a warning sign.
1.
Replace the lubricants before commissioning.
2. Check all O-rings that come into contact with the medium and
the mechanical seal and replace them if necessary as
described in
Ä
Chapter 6.3.3 “Replacing the mechanical
seal” on page 137.
3. Lubricate the adjustment mechanism as described in
Ä
Chapter 6.2.3 “Lubricating the adjustment mechanism and
the bearing” on page 127.
4. Observe the drive manufacturer’s instructions for storing the
drive.
5. Observe the manufacturer’s instructions for storing any
accessories.
Transportation, Storage and Installation