NOTE!
When using frequency converters
Due to their working principle, frequency converters generate
leakage current.
For proper operation of a frequency converter at a residual
current device, the use of an AC/DC sensitive residuaI cur-
rent device (type B) according to EN50178/VDE0160 is
required due to the DC component of the leakage current.
Operating manuals of electronic parts
Pay particular attention to all instructions
on safety,
on operation and control,
on repairs and maintenance,
in the operating manuals of electronic parts in the appendix.
The Börger machine must be completely installed before
establishing the electrical connections.
Be sure to read and follow all instructions:
on safety,
on operation and control,
on installation, repairs and maintenance.
Ä
Chapter 2.12
“Safety instructions for maintenance and rectifying malfunc-
tions” on page 37
1. Connect all electrical monitoring devices according to the
operating manuals from the manufacturers.
2. Connect the drive on versions with an electric drive
according to the operating manual from the manufacturer.
3. Ground the Börger machine properly, see operating manual
of the drive manufacturer. Also use the bore hole for the
ground terminal.
Transportation, Storage and Installation
BA-RC40_EN, 17.01.2024 www.boerger.de / www.boerger.com 85