EasyManua.ls Logo

Borger Bioselect RC 40 - Page 92

Default Icon
199 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTICE!
Risk of frost!
Pieces of ice in the separating and conveying unit or the freezing
of the brush auger onto the wedge wire screen can result in sub-
stantial damage to the screen upon resumption of operation.
Protect the Bioselect and the connections against frost.
The gear motor on the Bioselect must rotate counter-clockwise when
looking at the rear of the drive.
The brush auger must rotate clockwise when looking at the side with the
adjustment mechanism and the Multi Disc.
Read and follow the safety instructions detailed in
Ä
Chapter
2.12 “Safety instructions for maintenance and rectifying mal-
functions” on page 37.
After establishing the electric connections, check the direction
of rotation of the separator and the connected rotary lobe
pump (if applicable) by briefly switching on the drives (switch
off immediately after switching on!) and correct this if neces-
sary.
Transportation, Storage and Installation
BA-RC40_EN, 17.01.2024www.boerger.de / www.boerger.com92

Table of Contents