EasyManua.ls Logo

Case 621G - Page 226

Case 621G
430 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-MAINTENANCE
Cautionmasterindicator(yellow,non-critical)
Thecautionmasterindicatorisanon-criticalwarningdisplay.Seethe“Non-criticalwarnings”
table.WhenthecautionmasterindicatorisON,changetheoperatingmethod,schedulea
shutdownformaintenance,oriftheconditionpersists,contactyourdealer.
The“Non-criticalwarnings”tablelistswarningdisplaysthatmayappearontheinstrumentclusterandthecorrective
actionrequired.
NOTICE:whenafaultoccurs,anaudiblealarmmaysoundandtheCautionMasterIndicatorwillbeyellow.The
cautionmessagewillbedisplayedinthemessagearea.Ifthisoccurs,returnthemachinetoaserviceposition,and
turntheengineoff,andtakecorrectiveactiontohelpavoidexpensiverepairs.
Non-criticalwarnings
Display
Description
Correctiveaction
DEF/ADBLUE®
LevelLOW
DEF/ADBLUE®levelisless
than10%oftankvolume.
Noenginepowerlossatthis
level
FilltheDEF/ADBLUE®tank.
PoorDEF/
ADBLUE®quality
detected
PoorDEF/ADBLUE®
quality/concentration
detected.Aftertheengine
hasrunfor50minwithpoor
DEF/ADBLUE®quality,there
willbeatorqueandspeed
reduction.
Drainthetank.ReplaceDEF/ADBLUE®.
NOTE:seeDEF/ADBLUE®tankrelling”sectionforimportant
tankdraininginformation.
DEF/ADBLUE®
InjectionFailed,
PowerLimited
Technicalfailuredetected.
25%torquereductionramped
inwithin25min.Further
torque/speedreduction2h
afterinitialfaultdetectionif
faultdoesnotheal.
Contactyourauthorizeddealer.
Fuel
Lowfuel
Fillthefueltank-donotallowthetanktototallyempty.
7-18