9 - DIAGNOSTICS
DIAGNOSTICA (ME)
ME2000S - User Manual
123 - 133
CODE MESSAGE DESCRIPTION SOLUTION
27 Motor x (Zero: Motor busy) Internal error
Turn o󰀨 the machine and wait a few
seconds. Verify if a plate remains
jammed. Start and re-initialize the
machine. If the error still occurs,
contact Service Support.
28 Motor y (Generic)
Y motor driver error
Turn o󰀨 the machine and wait a few
seconds. Verify if a plate remains
jammed. Start and re-initialize the
machine. If the error still occurs,
contact Service Support.
29 Motor y (Driver generic)
30 Motor y (Driver high Z)
31 Motor y (Driver busy)
32 Motor y (Driver direction)
33 Motor y (Driver status)
34 Motor y (Driver command)
35 Motor y (Driver step mode)
36 Motor y (Driver under-voltage)
37
Motor y (Driver under-voltage
ADC)
38 Motor y (Driver over-current)
39 Motor y (Driver thermal)
40
Motor y (Zero: First zero active
not detected)
Error during the reset of axis Y
Check the “Y-motor” sensor and/or
switch o󰀨 the machine and check the
motor movement. If the error is still
present, contact technical support.
41
Motor y (Zero: Zero not active not
detected)
42
Motor y (Zero: Second zero active
not detected)

Table of Contents