DescriptionError/Warning MessageError/Warning
ID
This error can occur during an attempt
to apply a BLSR protection operation
to a line.
A card communication failure occurred during the
operation.
EID-2114
There was an error in applying the
specified operation.
An error occurred during the operation. {0}EID-2115
The extension byte set for the
specified ring is invalid.
The extension byte setting for the ring is invalid. {0}EID-2116
Clear all the protection operations for
the ring before deleting it.
The ring cannot be deleted. A protection operation is
set. All protection operations must be clear for ring to
be deleted.
EID-2118
Clear all protection operations or
switches before deleting the ring.
{0} cannot be deleted because a protection switch is in
effect. Please clear any protection operations, ensure
that the reversion time is not "never" and allow any
protection switches to clear before trying again.
EID-2119
The specified nodes could not be
unprovisioned. Try deleting this BLSR
or MS-SPRing later.
The following nodes could not be unprovisioned {0}
Therefore you will need to delete this {1} again later.
EID-2120
CTC cannot upgrade the specified
ring.
The ring cannot be upgraded. {0}EID-2121
You have selected an incorrect ring
speed for upgrade. Only rings within
the specified parameters can be
upgraded to 4-fiber BLSR.
The ring speed for is inadequate for the upgrade
procedure. Only {0} (or higher) {1} can be upgraded
to four-fiber.
EID-2122
Nonupgradable nodes. Verify that the
specified nodes have at least two
IS-NR ports with the same speed as
the 2-fiber BLSR. The specified ports
cannot serve as a timing reference, and
they cannot have data communications
channel (DCC) terminations or
overhead circuits.
Verify that the following nodes have at least two
in-service ports with the same speed as the two-fiber
{0}. The ports cannot serve as timing references, and
they cannot have DCC terminations or overhead
circuits. {1}
EID-2123
Refer to the error message text.You cannot add this span because it is connected to a
node that already has the east and west ports defined.
EID-2124
Refer to the error message text.You cannot add this span as it would cause a single
card to host both the east span and the west span. A
card cannot protect itself.
EID-2125
There is an Open Shortest Path First
(OSPF) area error.
An error occurred while provisioning the OSPF area.
{0}
EID-2126
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
489
Error Messages
Error Messages Reference