InteliDrive DCU Industrial 3.4.0 Global Guide
180
Related FW 3.4.0 Related applications AS, SS
Comm object 167
Description
This input changes state of logical binary output Droop Sw that can be configured as J1939 output to
change ECU mode. Input is active only when Basic setting: Governor Mode = BIN.INPUT (DROOP when
closed).
BI Droop
6 back to List of LBI
Related FW 3.4.0 Related applications AS, SS
Comm object 168
Description
This input changes state of SECOND RPM SW (SS ONLY) (PAGE 202) that can be configured as J1939 output
to change ECU mode. Input is active only when Speed Select (page 106)t = BIN.INPUT.
BI Second RPM
6 back to List of LBI
Related FW 3.4.0 Related applications AS, SS
Comm object 169
Description
This input changes state of IDLE/NOMINAL (PAGE 197) that can be configured as J1939 output to change
ECU mode. Input is active only when Idle/Nominal (page 105) = BIN.INPUT.
BI Idle
6 back to List of LBI
Related FW 3.4.0 Related applications AS, SS
Comm object 172
Description
Rem Start/Stop is level signal that activates engine start when closed and stop after is opened. It is inactive
in LOC (Local) mode.
It is not possible to stop engine by panel Stop button and by Remote Stop (page 172) when Rem Start/Stop
is active. Rem Start/Stop input can be configured to Binary output Timer active to enable engine automatic
start/stop function see Timer Repeat (page 108).
Note: Engine Start fail” is Warning (level 1) protection and does not block another start when Rem
Start/Stop is still closed. To prevent unlimited number of starts configure on START FAIL (PAGE 225)
Sd protection.
Note: Engine stays running when Rem Start/Stop is opened in controller LOC (Local) mode.
Rem Start/Stop