InteliDrive DCU Industrial 3.4.0 Global Guide
196
Related FW 3.4.0 Related applications AS, SS
Comm object 260
Description
CPU indication – output is closed when CPU is ready.
CPU Ready
6 back to List of LBO
Related FW 3.4.0 Related applications AS
Comm object 261
Description
Output is closed if REM CLUTCH (PAGE 174) is active or controller front panel I/0 button is pressed and actual
engine RPM is between: ClutchMinSpeed and ClutchMaxSpeed.
Output stays closed even if the RPM goes out of limits above. Can’t be opened by button when REM
CLUTCH (PAGE 174) is closed. BI Rem clutch is not active in LOC (Local) mode.
Clutch Connect
6 back to List of LBO
Related FW 3.4.0 Related applications AS, SS
Comm object 1461
Description
The first press of 0/1- panel Close Load button activates the new LBO ClutchBtToggle, the second press
deactivates it, The function operates in all engine modes and states and can be used for some independent
PLC function when standard Clutch function is not used.
Existing function of panel Close load button 0/1(LBO Close Load) is without change.
Close Load function works for remote access from DriveMonitor, Modbus, Modem, ... as well.
ClutchBtToggle