InteliDrive DCU Industrial 3.4.0 Global Guide
260
Value group Engine values Related FW 3.4.0
Resolution [units] 1 [°C]
Comm object 11569 Related applications AS, SS
Description
Internal value corresponding to logical input OIL TEMP (PAGE 235).
Oil Temp
6 back to List of values
Value group Engine values Related FW 3.4.0
Resolution [units] 0,1 [%]
Comm object 11570 Related applications AS, SS
Description
Internal value corresponding to logical inputFUEL LEVEL (PAGE 236).
Fuel Level
6 back to List of values
Value group Engine values Related FW 3.4.0
Resolution [units] [-]
Comm object 16071 Related applications AS, SS
Description
A value belonging to a particular Volvo Penta device - Power Module. Communication over the J1587
interface.
Data message PID 150 - PTO Engagement Control Status
Identifies the current state of the input and output functions used to control the engagement of PTO devices.
PrimBatActive binary status
SecBatActive binary status
D12ExhTemp binary status
D12SeaWatPres binary status
EMSSupply10A binary status
ExtraSupply7A binary status
30Supply7A binary status
PM Status
6 back to List of values