Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 68 © 2013 Cyan, Inc. – All Rights Reserved. 700-0023-05-00 Rev. 1
• G.975.1 Appendix 7 Universal Forward Error Correction (UFEC)
• Physical: Front access, fixed wavelength XFP optics
• Transponder and regeneration functions in conjunction with Z-Series LAD modules
2.3.3 Management
• Standard SONET/SDH OTN General Communication Channel (GCC0)
• A – Z circuit provisioning using Planet Operate
• SNMP v2
• CLI
• TL1
2.3.4 Physical
• Module dimensions:
Depth: 11.6" / 295 mm
Width: 1.2" / 30.5 mm
Height: 13.8" / 350 mm
• Weight: 4 lbs / 1.8 kg
2.3.5 Power
• Dual -48V DC power feeds to module slots
• Power consumption: 55 watts typical, 65 watts maximum
2.3.6 Environmental
• +32°F to +122°F / 0°C to +50°C operating temperature
• 5% to 85% operating relative humidity (non-condensing)
• 13,000 feet (4,000 m) altitude
2.3.7 Compliance / Safety
• NEBS 3 Certified (GR-63 CORE, GR-1089)
• UL/CSA Listed
• UE/CE-Marked: EN 60950, EN 55022, EN 6 1000, ETSI EN 300 386 V.1.3.3
• CB Scheme Certified 60950
• FCC, Subpart B, Part 15, Class A
• RoHS compliant