Cyan Z-Series Engineering and Planning Guide Release 5.0
700-0023-05-00 Rev. 1 © 2013 Cyan, Inc. – All Rights Reserved. Page 85
2.6.1 System Requirements
Cyan Z77, software version Release 5.0 or higher
2.6.2 Ethernet Services and Standards
• MEF EPL, EVPL and E-LAN services with local bridging between UNI-N and NNI port
• VLANs (IEEE 802.1Q)
• Q-in-Q (IEEE 802.1ad)
• MAC bridging (IEEE 802.1D)
• 2,000 TESIs
• Connection oriented Ethernet (COE) support:
Provider Backbone Bridging - IEEE 802.1ah
Provider Backbone Bridging (Traffic Engineering) - IEEE 802.1Qay
• Ethernet Ring Protection ITU-T G.8032v2 with sub-50ms switch times
• Spanning tree (IEEE 802.1D), multiple spanning tree (IEEE 802.1s), and Rapid Spanning Tree
(IEEE 802.1w) support (planned for a future release)
• P-bit priority QoS (IEEE 802.1p)
• 8 class of service queues per port
2.6.3 Optical Transport
• 4 x 10 GbE XFP, plus 6 x 10 GbE SFP+
• All ports support optional OTU2
• ITU-T G.975 Generic Forward Error Correction (GFEC) and Enhanced Forward Error Correction
(EFEC)
2.6.4 Interfaces
• 10 x 10 GbE LAN/WAN
• Physical: Front access, XFP and SFP+
2.6.5 Management
• ITU-T G.709 and OTN support on all DWDM interfaces
• SNMP v2
• CLI and TL1
• A – Z circuit provisioning using Planet Operate (TESI provisioning only in this Release)
2.6.6 Physical
• Module dimensions:
Depth: 11.6" / 295 mm
Width: 1.2" / 30.5 mm
Height: 13.8" / 350 mm
• Weight: 4.0 lbs / 1.8 kg