Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 74 © 2013 Cyan, Inc. – All Rights Reserved. 700-0023-05-00 Rev. 1
2.4.9 Power
• Dual -48V DC power feeds to module slots
• Power consumption: 88 watts typical, 126 watts maximum
Note: This reflects the typical power requirements of 4 XFP and 12 SFP transceivers.
2.4.10 Environmental
• +32°F to +122°F / 0°C to +50°C operating temperature
• 5% to 85% operating relative humidity (non-condensing)
• 13,000 feet (4,000 m) altitude
2.4.11 Standards
• MAC bridging (IEEE 802.1D)
• VLANs (IEEE 802.1Q)
• Q-in-Q (IEEE 802.1ad)
• Provider Backbone Bridging (PBB) IEEE 802.1ah
• Provider Backbone Bridging - Traffic Engineering (PBB-TE) IEEE 802.1Qay
• Spanning tree (IEEE 802.1D)
• Multiple Spanning Tree (IEEE 802.1s)
• Rapid Spanning Tree (IEEE 802.1w)
• Link OAM (IEEE 802.3ah Clause 57)
• Connectivity Fault Management (IEEE 802.1ag)
2.4.12 Compliance / Safety
• NEBS 3 Certified (GR-63 CORE, GR-1089)
• UL/CSA Listed
• UE/CE-Marked: EN 60950, EN 55022, EN 6 1000, ETSI EN 300 386 V.1.3.3
• CB Scheme Certified 60950
• FCC, Subpart B, Part 15, Class A
• RoHS compliant