Cyan Z-Series Engineering and Planning Guide Release 5.0
700-0023-05-00 Rev. 1 © 2013 Cyan, Inc. – All Rights Reserved. Page 31
• Carrier Ethernet Protection:
IEEE 802.3ad Link Aggregation
IEEE 802.3Qay Path Protection
ITU-T G.8032 Ethernet Ring Protection
• SONET/SDH Protection:
1+1 APS/MSP
UPSR/SNCP
1.2.1 Z33 Shelf Description
The Cyan Z33 I-Temp system employs advanced technologies, with high-density modularity in a compact
5
RU high, 19" (48.26 cm) wide chassis. Optimized for low entry costs, the Z33 shelf has six horizontal
service module slots and two common equipment slots supporting a wide range of advanced services and
network topologies.
• Line card (module) slots: 6
• Common control module slots: 2 (A and B)
• 1+1 equipment protection
• ITU timing
• All front access line cards and card interface connections
• Power connectors: Dual-feed Quick-Connect Terminal Block
• Alarm connectors: Quick-Connect Terminal Block
• Management connectivity: RJ-45 (10/100/1000Base-T)
All shelf components are modular and can be removed and replaced in the field. This provides full
serviceability and a simple upgrade path for future expansion. Each Z33 shelf ships with following items:
• (1) Front protective shield
• (1) Cable management guide
• (3) 12-position plug terminal block, 3.5 mm, 16–28 AWG
• (1) Ground cable
• (1) Power cable assembly
• (1) Fan module
• (1) Fan air filter
Z33 shelves should be installed in accordance with the Cyan Z33 Installation and Safety Guide. This will
ensure correct installation of modules, all associated wire management, power and grounding requirements,
and related components.