2.8.3 Management
• G.709 and OTN support on all DWDM interfaces
• A – Z circuit provisioning using Planet Operate
• SNMP v2
• CLI and TL1
2.8.4 Physical
• Module dimensions:
Depth: 11.6" / 295 mm
Width: 1.2" / 30.5 mm
Height: 13.8" / 350 mm
• Weight: 4.80 lbs / 2.177 kg
2.8.5 Power
• Dual -48V DC power feeds to module slots
• Power consumption: 140 watts typical, 175 watts maximum
Note: This reflects the typical power requirements of 4 XFP and 6 SFP+ transceivers.
2.8.6 Environmental
• +32°F to +122°F / 0°C to +50°C operating temperature
• 5% to 85% operating relative humidity (non-condensing)
• 13,000 feet (4,000 m) altitude
2.8.7 Compliance / Safety
• NEBS 3 Certified (GR-63 CORE, GR-1089)
• UL/CSA Listed
• UE/CE-Marked: EN 60950, EN 55022, EN 6 1000, ETSI EN 300 386 V.1.3.3
• CB Scheme Certified 60950
• FCC, Subpart B, Part 15, Class A
• RoHS compliant