Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 84 © 2013 Cyan, Inc.All Rights Reserved. 700-0023-05-00 Rev. 1
Features and Benefits
200 Gbps switch capacity per module.
High density 10 GbE interface connectivity.
Aggregation of 10G on the blade or across chassis using the XC-2800 Z77 switch fabric modules.
A-to-Z provisioning of Ethernet services across multi-layer Ethernet, Ethernet transport, OTN,
and DWDM.
Advanced MEF Ethernet services (E-Line, E-LAN).
Connection Oriented Ethernet – IEEE 802.1ah for high performance transport and network
efficiency.
Ethernet switch functionality provides the flexibility to augment or replace existing switches
or routers.
Upgrading capacity and functionality.
Easy migration of services from legacy Ethernet switches – for redeployment and reuse in
lesser transport intensive applications.
ITU-T G.975 Generic Forward Error Correction (GFEC) on DWDM trunk (5-6dB link
improvement).
OTU2 service identifiers on DWDM trunks for granular tracking and visibility.
Span by span, per-service transmit and receive performance monitoring with 15-min and 24-hr PM
statistics.
Supports removable XFP and SFP+ transceivers for client interface reach flexibility.
PSW-10G10 In-Band Management Channel
The PSW-10G10 module provides an optional in-band management channel of up to 100 Mbps in
bandwidth. If the Z77 shelf is configured with a PSW-10G10 line card and the shelf does not have a LAD or
WSS/AWG module or the traffic-carrying PSW interfaces are not fiber patched to an installed LAD or
WSS/AWG module, set the 10GE/OTU2 Fiber Port Signal Type parameter (General sub-tab) to "10GE
LAN" (default). When the PSW 10G fiber port is provisioned with a signal type of 10GE LAN or 10GE
WAN, the Topology Discovery and Routing parameters are automatically enabled (default) and the system
will use the PSW line card in-band management channel to provide node-to-node communication.
If the PSW-10G10 line card is installed in a Z77 shelf and a LAD or WSS/AWG module is providing the
OSC and the traffic-carrying PSW interfaces are fiber patched to a LAD or WSS/AWG module, Cyan
recommends that you set the PSW 10GE/OTU2 Fiber Port Signal Type parameter to "OTU-2" (General
sub-tab). When the PSW fiber port is provisioned with a signal type of OTU2, the Topology Discovery and
Routing parameters are automatically disabled and the PSW line card 100 Mbps of bandwidth that was
reserved for the in-band management channel is returned to the PSW 10G fiber port for payload. Disabling
Topology Discovery also prevents the system from displaying a topology line in addition to the OSC line to
the adjacent node in the 3D Network view tab.