TROUBLESHOOTING
91
SC5100 CONTROLLER
191
Fieldbus Mis-
match
Error
Fieldbus mod-
ule type does not
match specified
model.
Module selec-
tion incorrect
compared to the
actual module
installed.
193
Fieldbus Config
Error
Error
Error configuring
fieldbus module.
Unable to com-
municate to the
module.
Confirm that the
unit is not commu-
nicating to the
host.
Confirm that the
fieldbus parame-
ters are configured
properly (see
“Fieldbus” on
page 122).
Replace field-
bus module.
195
Fieldbus DHCP
Error
Error
Profinet module
had a DHCP
error.
Unable to acquire
an IP address.
Confirm that the
unit is not commu-
nicating to the
host.
Confirm that the
fieldbus parame-
ters are configured
properly (see
“Fieldbus” on
page 122).
Replace field-
bus module.
205
APD Tempera-
ture Error
Error
APD Tempera-
ture sensor is
not working. A
fluctuation in the
scanner's tem-
perature can
have an adverse
effect on several
internal func-
tions of the
scanner. The
scanner moni-
tors the tem-
perature, and if it
is erratic, this
error is posted.
The scanner may
experience an
increase in no-
reads.
The scanner may
start miss- ing
the transmit
point.
Cycle power on the
scanner;
Wait until the unit
has time to cool
down.
Restart the scan-
ner and moni- tor it
to determine
whether the error
reoccurs.
This is an inter-
nal failure and is
not field ser-
vice- able.
Replace scanner.