Loading...
30 Dell Converged Enhanced Ethernet Command Reference
53-1002115-01
show logging
2
show logging
Displays the internal syslog buffer of the switch.
Synopsis show logging
Operands none
Defaults There are no default configurations for this command.
Command
Modes
Privileged EXEC mode
Description Use this command to display the RASlog messages stored in the internal buffer.
Usage
Guidelines
The RASlog messages contain the module name, error code, and message details.
Examples To display the syslog messages stored in the internal buffer:
switch#show logging
Fabos OS Version: v6.1.2
Number of Messages: 1024
2009/02/03-00:19:43: %NSM-4-1001: Interface InTenGigabitEthernet 0/4 is
online.
2009/02/03-00:20:14: %NSM-4-1002: Interface InTenGigabitEthernet 0/4 is
protocol down.
2009/02/03-00:20:14: %NSM-4-1001: Interface InTenGigabitEthernet 0/4 is
online.
2009/02/03-00:21:10: %NSM-4-1003: Interface Port-channel 10 is link down
See Also none