EasyManua.ls Logo

Dell 8 - Switchport Converged

Dell 8
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Dell Converged Enhanced Ethernet Command Reference 53
53-1002115-01
switchport converged
3
switchport converged
Adds or removes native and tagged VLANs on a Layer 2 interface.
Synopsis switchport converged {vlan vlan_id | allowed vlan {add vlan_id | all | except vlan_id | none |
remove vlan_id}}
no switchport converged
Operands vlan vlan_id Sets the default native VLAN for the Layer 2 interface.
allowed vlan Sets the VLANs that will transmit and receive through the Layer 2 interface.
add vlan_id Adds a VLAN to transmit and receive through the Layer2 interface. The range
of valid values is 2-3583.
all Allows all VLANs to transmit and receive through the Layer 2 interface.
except vlan_id Allows all VLANs except the VLAN ID to transmit and receive through the Layer
2 interface. The range of valid values is 2-3583.
none Allows no VLANs to transmit and receive through the Layer 2 interface.
remove vlan_id Removes a VLAN that transmits and receives through the Layer 2 interface.
The range of valid values is 2-3583.
Defaults The default native VLAN for a converged interface is 1.
Command
Modes
Interface configuration mode
Description Use this command to add or remove tagged VLANs on a Layer 2 interface.
Usage
Guidelines
There are no usage guidelines for this command.
Examples To set the native VLAN of 200 on an interface:
switch(conf-if-te-0/19)#switchport converged vlan 200
To set the tagged VLAN on an interface to 100:
switch(conf-if-te-0/19)#switchport converged allowed vlan add 100
To remove the tagged VLAN 100 from the interface:
switch(conf-if-te-0/19)#switchport converged allowed vlan remove 100
See Also show vlan brief, show interface switchport, switchport mode, switchport trunk

Table of Contents

Other manuals for Dell 8

Related product manuals