Table 36. Warning events (continued)
Event Code Message Text and Description Details and Solution
4014 Library test failed due to a Drive issue.
v Verify the test parameters, and retry the test.
v If the test fails, check the library event log for
specific events that are associated with this
drive.
v Use the Management GUI to pull a drive
support ticket and check the device analysis
section for help.
4015 Power supply failed. Redundancy is not
available.
Ensure that all power supplies are installed
properly (two per module), and that each power
supply is connected to a valid power source.
4016 Back up configuration data to base module
failed.
Attempt to save the library configuration, power
cycle the library, and retry the operation.
4017 Restore configuration data from Chassis
failed.
Attempt to save the library configuration, power
cycle the library, and retry the operation.
4018 Firmware upgrade failed, tape drive
reported an error while the firmware file
was applied.
Verify that the firmware file is correct for the
drives, ensure that the drives are in a healthy
state with no cartridge in the drive, then retry
the operation.
4019 Drive Firmware bundle upgrade failed. Verify that the firmware file is correct for the
drives, ensure that the drives are in a healthy
state with no cartridge in the drive, then retry
the operation.
4020 Database was reset due to a problem that
prevented the library from powering up.
v If the library was restored to default settings,
restore a saved configuration by using a
previously saved config file.
v If no config file exists, then proceed in
configuring the library.
4021 Drive was hot-removed while in active
status as data transfer device.
v Put the drive back into the library.
v Follow the “Removing a tape drive” on page
108 procedure to remove the tape drive.
4025 Library test failed due to a cartridge error. Remove the cartridge and inspect it for damage.
Retry operation with another cartridge.
4028 Library Test failed due to incompatible
media.
Check LTO generation for media and drives.
Remove cartridges that are not compatible to
your tape drives.
4029 Library Test failed - Cartridge bar code
indicates incompatibility with drive.
Check if Media bar code label is matching LTO
generation. Replace the label or remove
incompatible media from your system.
4030 Move cartridge operation failed due to
media error.
Remove the cartridge and inspect it for damage.
Retry operation with another cartridge.
4041 Library Verify failed because the power
supply redundancy test failed.
Ensure that all power supplies are installed
properly (two per module), and that each power
supply is connected to a valid power source.
4044 One of the Library tests failed because a
source element or destination element is not
accessible.
Verify the source and destination elements and
retry the move operation.
4059 Drive configuration failed because it does
not support encryption.
Replace drive by a model of LTO generation 4 or
higher or disable encryption for this logical
library.
88 Dell EMC ML3 Tape Library: User's Guide