Installing the drive cage
This is a service technician replaceable part only.
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the front top cover.
4. Remove the cooling fan cage assembly.
5. Remove the air shroud .
6. Remove the drives.
7. Observe and disconnect the drive backplane cables from the connector on the system board and backplane.
8. Remove the drive backplane.
9. Slide out the drive cage.
Steps
1. Using both hands, hold and slowly push the drive cage toward the rear of the server.
Figure 63. Installing the drive cage
2. Align and place the metal plates on both sides of the chassis.
3. Using Phillips 2 screwdriver, tighten four capture screws to secure the drive cage with metal plates on both side of the
chassis.