Loading...
9
Reconnect cables to connection board. See the Board Layout section in this manual for
connector assignments.
Note!
There are several 4-pin connectors on the board. The RS-485 connectors are 4-pin, and the
24V in from the power supply, and the 24V out to the SPM’s are also 4-pin. Reconnecting
cables to the wrong 4-pin connectors may damage the iX boards, and other components.
10
Reconnect bottom left cable to the ISB and resecure ISB to vapor barrier.
11
Reinstall cover on ISB and reconnect the top cables.
12
Turn on power and test all dispenser operations.
Figure 6.69: ISB Side A and Side B