7.1 Bootstrap Procedure
The Bootstrap procedure listed below must be performed if: 1) after selecting filename or template
in Function 98 or 99, the process of downloading to the pump computer is interrupted, or 2) a
pump computer is installed that does not have pump software code already onboard.
To Bootstrap the iGEM computer:
1
Power down iGEM computer at the dispenser power switch.
2
Connect laptop via RS-232 cable and adapter to J18 or use null modem cable to J26 on the
computer board. See iGEM connector locations in the Board Layout section of this manual.
3
Remove Current Loop jumper S12D.
4
Press and hold S13 push button.
5
Power up iGEM computer.
6
Release S13 push button.
7
Open the servTerm program.
8
Click on iGEM Bootstrap Connect.
9
Select the __.bin file (pump code or template file) to download to the dispenser. An example
is shown in the Figure below.
10
Downloading blocks begin and then the message download complete is displayed.
11
Click on iGEM Disconnect.
12
Reinstall Current Loop jumper S12D.
13
Power down iGEM.
14
Disconnect laptop cable.
15
Power-up iGEM.
Figure 7.1: Select Pump Code File
When downloading pump code, select the correct pump File Name such as, iGEM_62.bin. Do
not select flash LDR.bin file as this is not a pump code file.
WM048523 Rev 08 01/2019 167
7 iGEM Software Downloads - IEC version