6.18 24V Power Supply Replacement
1
Turn off power at the dispenser power switch.
2
Disconnect DC cable on right side of power supply. Fig 6.73.
3
Remove (4) 3 mm Allen screws that secure the assembly to the mounting bracket.
4
Slide the power supply to the left, pull out, then disconnect AC cable and remove power
supply.
5
Install new power supply.
6
Reconnect cables.
7
Reinstall protective cover.
Figure 6.73: Power Supply AC and DC Cables